Operations
Place hands under the faucet. The valve will turn on allowing the water to flow. When hands are removed the valve is closed and the wate flow is stopped.
Set Sensor Range Adjustments
No adjustments are required for most settings.Factory default range is 55 – 60 mm. The factory setting should be satisfactory for most
installations.Sensor range can be adjusted after power is supplied to the faucet. The sensor range is dependent on the distance of your hand or card while sensor is in range setting mode. If no target is placed in front of the sensor, the sensor range will set to its longest distance.Place your hand or card in front of the sensor at the distance you desire the faucet to activate.Leave the target at this location while the sensor range is setting. Remove hand or card after 30 seconds or when the LED is off. The sensor range is now set.
Care & Cleaning
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucet that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect
the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating.